Fluke 114 Digital Multimeter - Electrical
 The Fluke 114 Multimeter is the ideal choice for "go / no-go testing". It is designed for easy one-handed operation. It is a compact and True RMS digital multimeter. 
 Key Features
  - Ideal digital multimeter for "go/no-go" testing
- Features AutoVolt automatic AC/DC voltage selection
- Includes low input impedance to help prevent false readings due to ghost voltage
- Large white LED backlight display for working in poorly lit areas
- Measures resistance, continuity, frequency, and capacitance
- Provides Min/Max/Average with elapsed time to record signal fluctuations
- Features a compact ergonomic design for one-handed operation
- Comes with a holster (with probe holders) for easy storage
- Features manual and automatic ranging
- Safety rates CAT III 600 V
- Fits into optional ToolPak magnetic hanger for hands-free operation
Specification
     | Specification | 
  | Maximum voltage between any terminal and earth ground | 600 V | 
  | Surge protection | 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 | 
  | Display | Digital: 6,000 counts, updates 4 per second | 
  | Bar graph | 33 segments, updates 32 per second | 
  | Operating temperature | -10°C to + 50°C | 
  | Storage temperature | -40°C to + 60°C | 
  | Battery type | 9 volt Alkaline, NEDA 1604A / IEC 6LR61 | 
  | Battery life | 400 hours typical, without backlight | 
  | Accuracy specification | 
  | DC millivolts | Range/resolution | 600.0 mV / 0.1 mV | 
  | Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | 
  | DC volts | Range/resolution | 6.000 V / 0.001 V60.00 V / 0.01
 V600.00 V / 0.1 V
 | 
  | Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | 
  | Auto volts | Range/resolution | 600.0 V / 0.1 V | 
  | Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz)
 | 
  | AC millivolts1 True RMS | Range/resolution | 600.0 mV / 0.1 mV | 
  | Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
 | 
  | AC volts1 True RMS | Range/resolution | 6.000 V / 0.001 V60.00 V / 0.01
 V600.0 V / 0.1 V
 | 
  | Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
 | 
  | Continuity | Range/resolution | 600 Ω / 1 Ω | 
  | Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
 | 
  | Ohms | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ
 60.00 kΩ / 0.01 kΩ
 600.0 kΩ / 0.1 kΩ
 6.000 MΩ / 0.001 MΩ
 | 
  | Accuracy | 0.9% + 1 | 
  | Range/resolution | 40.00 MΩ / 0.01 MΩ | 
  | Accuracy | 5% + 2 | 
  | 1. All ac voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
 2. Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
 2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
 | 
  | Mechanical & General Specification | 
  | Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | 
  | Weight | 550 g | 
  | Warranty | 3 years |